Estimate what air conditioning costs per season from cooling capacity, SEER2 or CEER, compressor run-hours, and your electricity price.

CalculatorUpdated November 29, 20268 min read

Live calculator

What does air conditioning cost?

Enter the system’s cooling capacity, efficiency rating, run-hours, and your electricity price. The estimate covers one cooling season.

Presets are typical starting points, not tested models. Replace them with the rating on your unit’s label.
Btu/h
12,000 Btu/h is one ton. A central system is usually 2–5 tons; a window unit is 8,000–12,000 Btu/h.
Central systems use SEER2; room units use CEER. Higher is better. New central units generally start around 14.3–15.2 SEER2.
h/day
Count hours at full capacity, not hours the unit is switched on. If it runs half the time for 10 hours, enter 5.
days
Use the number of days you actually run the system, not the length of the calendar summer.
¢
Default: U.S. residential average, 18.17¢/kWh (EIA, September 2026).
Estimated cost per cooling season
$0
$0.00 per day in use · 0 kWh per season
Full-load draw 0 kW
Cost per run-hour $0
Electricity per season 0 kWh
CO₂ per season 0 lb
SEER2 and CEER are seasonal averages; part-load behavior varies Formula & assumptions

Air conditioning is the household load that can double a summer bill without changing anything you can see. The two numbers on the label — cooling capacity in Btu per hour and efficiency as SEER2 or CEER — describe the machine, but neither one is a dollar figure. This calculator turns them into a seasonal cost using the hours the compressor actually runs and the price you pay per kilowatt-hour.

The default is a 3-ton central system rated 15 SEER2, running the equivalent of five full-load hours a day for 120 days. At the U.S. residential average of 18.17¢/kWh, that comes to about $262 for the season — roughly $2.18 per cooling day and 1,440 kWh. A window unit is a different scale: 12,000 Btu/h at 12 CEER on that schedule costs about $109.

What a cooling season costs

The table holds the schedule constant — five equivalent full-load hours a day, 120 days, 18.17¢/kWh — and changes only the equipment.

System Capacity Efficiency Full-load draw kWh / season Cost / season
Window unit 8,000 Btu/h 11.5 CEER 0.70 kW 417 $76
Window unit 10,000 Btu/h 12.0 CEER 0.83 kW 500 $91
Window unit 12,000 Btu/h 12.0 CEER 1.00 kW 600 $109
Central, 2 tons 24,000 Btu/h 14.3 SEER2 1.68 kW 1,007 $183
Central, 3 tons 36,000 Btu/h 15.0 SEER2 2.40 kW 1,440 $262
Central, 3 tons 36,000 Btu/h 20.0 SEER2 1.80 kW 1,080 $196
Central, 4 tons 48,000 Btu/h 15.0 SEER2 3.20 kW 1,920 $349

Two things stand out. First, capacity matters more than efficiency at this scale: moving from a 2-ton to a 3-ton system adds about 43% to the seasonal bill, while moving from 15 to 20 SEER2 cuts it by 25%. Second, a window unit is not a miniature central system: it cools one room, so the comparison holds only if that is the job.

How the math works

Efficiency ratings convert capacity into power. SEER2 is measured in Btu of cooling per watt-hour of electricity over a season; CEER does the same job for room units. Divide capacity by the rating and you get the approximate full-load draw in watts.

full-load power (kW) = capacity (Btu/h) ÷ seasonal efficiency (Btu/Wh) ÷ 1,000
kWh per season = full-load power × equivalent full-load hours per day × cooling days
season cost = kWh × price per kWh
CO₂ = kWh × 0.771 lb

For the default: 36,000 ÷ 15 ÷ 1,000 = 2.4 kW. Multiply by 5 hours and 120 days: 1,440 kWh. At 18.17¢/kWh: $261.65, which rounds to $262. The carbon estimate is 1,440 × 0.771 = 1,110 lb CO₂, using the EPA eGRID 2023 U.S. average.

One ton is 12,000 Btu/h, so a 3-ton system has 36,000 Btu/h of capacity. That is roughly enough for a well-insulated 1,800–2,400 square-foot house in a moderate climate, but a real load calculation depends on windows, insulation, ceiling height, and local design temperatures.

Why run-hours are the hard part

The formula is simple; the hours are not. “Five hours a day” in this calculator means five equivalent full-load hours, not five hours with the thermostat switched on. A unit that runs half the time for ten hours delivers the same cooling as five hours at full load. A unit that cycles for ten minutes every half hour is running at roughly one-third average capacity.

Using the hours the system is “on” overstates the electricity, because the compressor spends much of that time off; using the label’s maximum draw overstates it further.

Three practical ways to estimate it:

Weather is the other half. A 95°F week can double runtime compared with an 80°F week, and humidity adds load. The “cooling days” input is how many days the system actually runs, not the length of the calendar summer.

Window unit or central?

A window unit and a central system do different jobs. A 12,000 Btu/h window unit is one-sixth the capacity of a 3-ton central system and cools one room. If you spend the day in that room, it can be the cheaper way to stay comfortable; if you need the whole house cool, it may run continuously.

The ratings are not perfectly comparable either. Central systems use SEER2; room units use CEER. Both are seasonal metrics, but different test procedures and capacity ranges apply. Treat a CEER of 12 and a SEER2 of 15 as roughly similar in spirit, not interchangeable.

Ducts are the hidden difference. Central systems move air through ducts that may run through a hot attic, and leaks waste cooling before it reaches the room. The calculator does not model that penalty, so a central system’s real cost can be higher. A ductless mini-split avoids it and can fit a single room well.

Five ways to cut cooling costs

  1. Raise the setpoint, especially when away. A smart thermostat can schedule a warmer house during work hours and cool it before you return. A smaller indoor-outdoor temperature difference means less heat leaking in and less compressor work.
  2. Shade and seal before replacing equipment. Window film, exterior shade, weatherstripping, and attic insulation reduce the load. They are often cheaper than a new condenser and make any system perform better.
  3. Change the filter and clean the coils. Restricted airflow forces the blower to work harder and can ice the coil. A dirty outdoor condenser rejects heat less effectively.
  4. Do not oversize a replacement. A system that is too large cools quickly, then cycles off before it removes much humidity. Ask for a room-by-room load calculation rather than a rule-of-thumb match to the old unit.
  5. Compare seasonal savings, not just the label. The jump from 15 to 20 SEER2 saves about 25% of compressor energy in this model. Whether that justifies the price difference depends on climate, run-hours, and how long you stay.

What this calculator leaves out

The estimate covers compressor electricity only; the methodology page lists every default. It excludes the indoor fan, duct losses in central systems, standby power, and auxiliary heat. It also assumes the unit delivers rated capacity in your house: an undersized unit runs longer, and an oversized one cycles more.

It uses one average price. Time-of-use rates and tiered pricing can make the marginal cost of cooling higher, while fixed charges do not change with use.

Finally, SEER2 and CEER are laboratory ratings. They are useful for comparing equipment, not predicting a specific bill. Use the calculator to compare options — window versus central, 15 versus 20 SEER2, a mild versus a hot season — and see which input moves the result most.

For a whole-house view, pair this with the appliance energy cost calculator and the guide to what your electricity bill doesn’t tell you. The first breaks down the other big loads; the second explains why the number on the bill is not the same as the number you can control.

Questions

How much does it cost to run an air conditioner for an hour?

It depends on capacity and efficiency. A 3-ton central unit rated 15 SEER2 draws about 2.4 kW at full load; at 18.17¢/kWh that is roughly 44 cents per full-load hour. A 12,000 Btu/h window unit rated 12 CEER draws about 1 kW, or roughly 18 cents per full-load hour. Real average cost is often lower because the compressor cycles on and off.

What is SEER2, and how is it different from EER?

SEER2 is the seasonal energy efficiency ratio: cooling output in Btu divided by electricity input in watt-hours over a defined season, measured under a newer test procedure. EER2 measures efficiency at a single full-load condition. A higher SEER2 usually means lower seasonal energy use, but sizing, ducts, and part-load behavior still matter. Room air conditioners are rated with CEER, a separate seasonal metric.

Is it cheaper to turn the AC off when I leave the house?

For a typical single-speed system, raising the setpoint or turning the unit off while the house is empty usually saves energy. The recovery period runs longer when you return, but it rarely uses more than the energy saved during the setback. The exception is a system that struggles to recover in extreme heat or a home with humidity problems; in those cases a moderate setback is safer than a full shutdown.

Why is my actual bill higher than the calculator?

The estimate covers compressor electricity only. It excludes duct losses, the indoor fan, humidity control, and the extra runtime caused by a hot attic, leaky windows, or an undersized unit. It also uses one average electricity price, while many bills include tiered rates, time-of-use pricing, demand charges, and fixed fees. Treat the result as a seasonal estimate, not a prediction of a specific bill.

Sources & notes

Primary data and reference material used on this page.

  1. ENERGY STAR — Room Air Conditioners — room sizing chart, cooling capacity guidance, and room-unit efficiency context
  2. ENERGY STAR — Ductless Heating & Cooling — efficiency ratings and sizing context for ductless cooling systems
  3. ENERGY STAR — Save at Home: Heating & Cooling — thermostat schedules, maintenance, and contractor guidance
  4. EIA Electric Power Monthly, Table 5.6.A — U.S. residential average price of 18.17¢/kWh, September 2026
  5. EPA eGRID 2023 Summary Tables — U.S. total output emission rate of 770.9 lb CO₂e per MWh, used here as 0.771 lb/kWh
Editorial noteFigures are rounded for readability; calculations use the unrounded inputs shown in the methodology. Prices and grid factors change — treat every result as an estimate, not a bill.