An appliance’s label tells you the maximum power it can draw, not what it costs to run. A 1,500-watt space heater and a 1,500-watt kettle use the same electricity for the same number of minutes, but one might run for four hours a day and the other for three minutes. The difference in the annual bill is enormous.
This calculator converts three things — power, time, and your electricity price — into kilowatt-hours and dollars. The presets are typical average draws for common household devices, not laboratory maximums. Use them as a starting point, then replace them with your own measurement when accuracy matters.
The only formula you need
Electricity is billed by energy, not by power. A kilowatt-hour is one kilowatt (1,000 watts) used for one hour, or 100 watts used for ten hours. Everything else is multiplication.
annual cost = kWh × price per kWh
CO₂ = kWh × 0.771 lb (U.S. average grid factor)
For example: a device drawing 75 watts for 24 hours a day, 365 days a year, uses 657 kWh. At 18.17¢/kWh, that is about $119 a year and roughly 507 lb of CO₂.
A 1,500-watt space heater used 4 hours a day for 150 days uses 900 kWh, or about $164 and 694 lb of CO₂ for the season. Same formula, very different behavior.
Why the label is not the bill
Three things separate the nameplate wattage from the number your meter records.
Duty cycle. Motors, compressors, and thermostatically controlled heaters cycle on and off. A refrigerator’s compressor might draw 150–200 watts while running but average 50–100 watts over a day. A central air conditioner may draw 3,500 watts while the compressor runs, then drop to a few hundred watts for the fan. Using the peak number for 24 hours overstates the bill by a large factor.
Average versus peak. The preset list uses average draw for devices that cycle, and running draw for devices that are either on or off. A dryer is close to its running draw for the hour it operates; a fridge is not.
Standby and phantom loads. Electronics, set-top boxes, and chargers draw a little power when “off.” Individually, the numbers are small. Added across a house, they can be tens of watts — but usually less than a single incandescent bulb left on. Measure before you spend money chasing them.
The 100-watt rule
The most useful mental shortcut in household electricity: every 100 watts left running continuously costs about $159 a year at 18.17¢/kWh. That is 876 kWh.
| Continuous load | kWh per year | Cost at 12¢ | Cost at 18.17¢ | Cost at 25¢ | Cost at 35¢ |
|---|---|---|---|---|---|
| 10 W | 88 | $11 | $16 | $22 | $31 |
| 50 W | 438 | $53 | $80 | $110 | $153 |
| 100 W | 876 | $105 | $159 | $219 | $307 |
| 500 W | 4,380 | $526 | $796 | $1,095 | $1,533 |
| 1,500 W | 13,140 | $1,577 | $2,388 | $3,285 | $4,599 |
The table is why “just leave it on” is expensive for heaters and cheap for routers. It also shows why the price you pay matters: the same 100-watt load costs three times as much at 35¢ as at 12¢. If you live in Hawaii, New England, or California, the national average understates your bill; if you live in a low-rate state, it overstates it.
Which appliances deserve attention
Water heating is often the largest single electricity user in an electric home, after space heating and cooling. A resistance tank running three hours a day at 4,000 watts uses 4,380 kWh a year in this model — $796 at the national average. Heat-pump water heaters cut that by roughly two-thirds, which is why they are the first upgrade to evaluate when a tank fails.
Heating and cooling dominate where they exist. A central air conditioner at 3,500 watts for six hours a day over a 120-day cooling season uses 2,520 kWh. A window unit at 1,000 watts for the same schedule uses 720 kWh. The efficiency of the house — insulation, air sealing, shade — matters as much as the appliance.
Refrigeration runs constantly but at a low average draw. A new full-size fridge might use 400–600 kWh a year; an old one in a hot garage can use twice that. Replacing a working fridge purely for efficiency rarely pays back quickly, but a second fridge that holds a few drinks often does not justify its own meter.
Clothes drying is a concentrated load: roughly 3 kWh per electric load, or about 780 kWh a year at five loads a week. Line drying and heat-pump dryers are the two ways to cut it. The laundry calculator handles that comparison directly.
Pool pumps and dehumidifiers are the sleepers. A 1,000-watt pool pump running four hours a day costs about $265 a year at the national average, and a dehumidifier running eight hours a day for half the year costs about $79. Neither is visible in the same way as a heater, but both run for long stretches.
Electronics are usually smaller than people expect. A television at 100 watts for four hours a day is 146 kWh a year, about $27. A laptop at 50 watts for eight hours a day is 146 kWh as well. The category matters less than the hours.
How to measure your own appliance
The cheapest accurate method is a plug-in electricity meter, often sold as a “watt meter” or “energy monitor.” Plug the appliance into the meter, leave it for a representative week, and read the accumulated kWh. That captures duty cycles, standby draw, and your actual usage pattern in a way no label can.
If you do not want to buy a meter, the federal EnergyGuide label on major appliances gives an estimated annual kWh figure. Divide that by 365 to get average daily use, then multiply by your rate. For devices without a label, the presets here are a reasonable starting point.
A smart plug with energy monitoring can do the same job over time and is useful for devices that cycle unpredictably. For anything that runs on 240 volts — dryers, water heaters, central air — do not use a plug-in meter unless it is rated for that circuit; read the panel or the appliance’s own estimate instead.
What this calculator leaves out
The estimate treats electricity as a single price. Many utilities use tiered rates, where the marginal kilowatt-hour costs more once you cross a baseline, or time-of-use rates that vary by hour. It also excludes fixed charges and taxes, and it does not model the interaction between appliances and the home’s heating and cooling system. A refrigerator in a conditioned kitchen adds heat that the air conditioner must remove in summer; an incandescent bulb does the same. Those effects are real but second-order compared with the direct energy use.
For a whole-house view, add up the big categories rather than every device. The guide on what your electricity bill does not tell you explains how to do that without drowning in spreadsheets.
Questions
How many watts does a refrigerator use?
A modern full-size refrigerator usually averages somewhere between 50 and 100 watts over a full day, which works out to roughly 400 to 800 kWh a year. The compressor draws more while it is running and much less while it cycles off, so the label wattage is not the right number for an annual estimate.
Does unplugging phone chargers save money?
Very little. A charger with no phone attached typically draws a fraction of a watt. Even a few watts left on all year costs a dollar or two at typical U.S. rates. It is not nothing, but it is far less important than heating, cooling, hot water, and drying.
Are space heaters expensive to run?
Yes, because they convert electricity to heat at a one-to-one ratio. A 1,500-watt heater running four hours a day for 150 days uses about 900 kWh. At 18.17 cents per kWh that is roughly $164 for the season, before counting the other heaters in the house.
Why does my actual bill differ from the estimate?
The calculator uses a single average price. Real bills may include tiered rates, time-of-use pricing, demand charges, taxes, and fixed fees. Appliances also interact with heating and cooling: a fridge or dehumidifier adds heat to the room, while an air conditioner removes it. Treat the result as a directionally correct estimate.
Sources & notes
Primary data and reference material used on this page.
- ENERGY STAR — Products — appliance efficiency context and typical consumption ranges
- U.S. Department of Energy — Estimating Appliance and Home Electronic Energy Use — method for converting watts and hours into kilowatt-hours
- EIA Electric Power Monthly, Table 5.6.A — U.S. residential average price of 18.17¢/kWh, September 2026
- EPA eGRID 2023 Summary Tables — U.S. total output emission rate of 770.9 lb CO₂e per MWh