Measure / Calculator

Heating Cost Calculator

Compare a gas furnace, heat pump, and electric resistance heat on cost per million Btu, 10-year cash, carbon, and the fuel prices where each one wins.

CalculatorUpdated November 30, 20268 min read

Live calculator

Gas furnace, heat pump, or resistance?

Turn your current heating use into delivered heat, then compare three replacements on cost per million Btu, 10-year cash, and the fuel prices where each one wins.

Pick the fuel on your heating bill. The calculator converts it to delivered heat.
therms
A full year of bills, not a winter month. The default is an illustrative 600 therms.
%
AFUE × 100 for a furnace or boiler (80–98). Use 100 for electric resistance, or seasonal COP × 100 for an existing heat pump (HSPF2 ÷ 3.412 × 100).
years
Cash total, with fuel prices held flat. Add a replacement if a unit will not last the period.

Delivered heat: 54.0 MMBtu a year. That is the heat the house actually receives, after the current system's losses.

¢/kWh
Default: U.S. residential average, 18.17¢/kWh (EIA, September 2026).
$/therm
Default: $1.88/therm, the 12-month U.S. average through August 2026 (EIA, $19.47/Mcf ÷ 10.37).
$/gal
Default: $2.813/gal, U.S. residential average for the week of Nov. 23, 2026, excluding taxes (EIA).
$/gal
Default: $5.468/gal, U.S. residential average for the week of Nov. 23, 2026, excluding taxes (EIA).

Gas furnace

$
Equipment, labor, venting, removal, and permits. Use a written quote.
%
95 is high-efficiency condensing; 80 is standard. Use the rating on the unit.
$
Only a confirmed point-of-sale incentive; leave 0 if unsure.

Heat pump

$
May include a new circuit, line set, duct work, and removal. If it also replaces an air conditioner, enter only the added cost.
HSPF2
Seasonal Btu per Wh. ENERGY STAR split systems are at least 7.8; cold-climate ducted units at least 8.1. Use the label.
$
Utility and state rebates change; enter one only if confirmed. A tax credit is not a point-of-sale rebate.

Electric resistance

$
Baseboards, a furnace, or a boiler. Often the cheapest equipment to install.
COP
Resistance heat converts nearly all electricity to heat; the model uses COP 1.00.
$
Only a confirmed incentive; leave 0 if unsure.

Installed costs are planning figures, not national averages. The comparison is cash over the period: it does not discount future costs or predict fuel prices.

Lowest 10-year cost
$16,686

The three systems

Metric Gas Heat pump Resistance
Installed − rebate $6,000 $12,000 $2,500
Energy / year 568 therms 6,000 kWh 15,826 kWh
Energy cost / year $1,069 $1,090 $2,876
Period total $16,686 $22,902 $31,257
CO₂ lb/yr 6,651 4,626 12,202

Break-even · HP = heat pump

Comparison Tie / winner
Gas price vs HP $2.97/therm HP above
Power price vs HP 7.8¢/kWh HP below
HP vs resistance 5.3 years HP after

Cost per million Btu · accent = lowest

Fuel / system Efficiency $/MMBtu Cost/year
Natural gas 95% AFUE $19.79 $1,069
Propane 90% AFUE $34.18 $1,846
Heating oil 85% AFUE $46.45 $2,508
Heat pump 9.0 HSPF2 $20.19 $1,090
Resistance COP 1.00 $53.25 $2,876

Propane and oil rows assume 90% and 85% AFUE. The gas and heat-pump rows use the efficiencies entered above.

Delivered Btu = fuel × heat content × efficiency; period total = installed − rebate + annual cost × years Formula & assumptions

A heat pump is usually described as the efficient choice, and a gas furnace as the cheap one. Both can be true at once, because they answer different questions. The number that compares them fairly is cost per million Btu of delivered heat — fuel price divided by efficiency, with the units made to match. This calculator turns your current heating use into delivered heat, then prices a new gas furnace, a heat pump, and electric resistance on the same load.

The defaults describe a house using 600 therms a year at 90% AFUE: 54 million Btu of delivered heat. At 18.17¢/kWh, $1.88/therm, and the planning installed costs shown, the gas furnace has the lowest 10-year total ($16,686), the heat pump is $6,216 behind ($22,902), and resistance is last ($31,257). The surprise is how close the first two are to run: the heat pump costs about $1,090 a year and the gas furnace about $1,069. Gas wins on cash because it is cheaper to install, not because it uses less energy.

Cost per million Btu is the honest comparison

AFUE and HSPF2 are ratios with different denominators. AFUE is the share of fuel energy delivered as heat over a season. HSPF2 is Btu of heat per watt-hour of electricity. Converting both to dollars per million Btu puts them on one scale:

cost per MMBtu = price per unit ÷ (MMBtu per unit × efficiency)
natural gas: $/therm ÷ (0.1 × AFUE)
propane: $/gal ÷ (0.091452 × AFUE)
heating oil: $/gal ÷ (0.1385 × AFUE)
heat pump: $/kWh × 1,000 ÷ HSPF2
resistance: $/kWh × 293.1

At the defaults, gas is $19.79/MMBtu, the heat pump $20.19, propane $34.18, heating oil $46.45, and resistance $53.25. The heat pump and gas furnace are within 2% of each other; the other fuels are not close. That is why “heat pump vs gas” is a real argument and “heat pump vs oil” usually is not.

The conversion also explains the label: HSPF2 9.0 is a seasonal COP of about 2.64 (9.0 ÷ 3.412), so each unit of electricity delivers about 2.6 units of heat after defrost, cycling, and standby. A 95% furnace delivers 0.95.

The default example, step by step

Gas furnace Heat pump Electric resistance
Installed cost $6,000 $12,000 $2,500
Efficiency 95% AFUE 9.0 HSPF2 (COP 2.64) COP 1.00
Energy a year 568 therms 6,000 kWh 15,826 kWh
Energy cost a year $1,069 $1,090 $2,876
10-year total $16,686 $22,902 $31,257
CO₂ a year 6,651 lb 4,626 lb 12,202 lb

The heat pump uses 6,000 kWh to deliver the same 54 MMBtu; resistance needs 15,826 kWh. The gas furnace burns 568 therms. At these prices the two leading options are nearly tied to run, but the heat pump's $6,000 higher installed cost has to be repaid by a saving that does not exist. The break-even section shows what would have to change.

On carbon, the ranking flips. At the U.S. average grid factor of 0.771 lb CO₂/kWh, the heat pump emits 4,626 lb a year, the gas furnace 6,651 lb, and resistance 12,202 lb. Over 10 years the heat pump avoids about 20,200 lb versus gas and 75,800 lb versus resistance. A cleaner grid widens the gap; a coal-heavy one narrows it.

What would change the answer

Three prices move the ranking, and the calculator solves for each:

The cooling cost dataset lists the state prices behind that comparison, and the heating fuel cost dataset does the same for gas, propane, heating oil, and heat pumps in every state. The electricity guide explains why your marginal price can differ from the state average.

What HSPF2 hides

HSPF2 is a seasonal average for a standard climate and an average house. It does not promise the same efficiency in yours:

What the total leaves out

The comparison is cash over a period, not a full life-cycle cost. It excludes:

The bottom line

At the 12-month average gas price, the default example favors the furnace on 10-year cash; the heat pump is close to run but behind to install. At the latest monthly gas price, the heat pump is already cheaper to run. Against propane, oil, and resistance, the heat pump wins the operating comparison by a wide margin. The decision is local: your fuel, your rates, your quotes, and whether you need cooling.

Use written quotes for each option, then look at the two tie prices. If your gas price is above the tie, or your power price is below it, the heat pump's premium is being repaid. If neither is true, the furnace is the cheaper cash choice, and the heat pump is a carbon and cooling decision. The AC calculator prices the cooling side; the water heater calculator makes the same trade-off for hot water. The methodology page lists every default.

Questions

Is a heat pump cheaper to run than a gas furnace?

It depends on the price of each fuel, not on the labels. At the national defaults — 18.17¢/kWh and $1.88/therm — a HSPF2 9.0 heat pump costs about $20.19 per million Btu and a 95% AFUE gas furnace about $19.79, so they are nearly tied. The heat pump wins where electricity is cheap, gas is expensive, or the unit's HSPF2 is higher. In the default example gas has the lower 10-year total because the heat pump costs $6,000 more to install. Against propane, oil, or electric resistance, the heat pump's operating advantage is much larger.

What HSPF2 does a heat pump need to beat a gas furnace?

At 18.17¢/kWh and $1.88/therm, a heat pump needs about HSPF2 9.2 to match a 95% furnace on operating cost alone. That is within the range of cold-climate models: ENERGY STAR requires at least 8.1 for ducted cold-climate split systems and 8.5 for non-ducted, and high-end units exceed 10. But at a $6,000 installed premium, the heat pump also needs gas above about $2.97/therm to win over ten years; efficiency alone does not close the capital gap.

Why does the calculator ask for my fuel use instead of my square footage?

Square footage does not determine heat loss. Insulation, air sealing, windows, climate, and thermostat habits matter as much. A year of fuel bills measures the result of all of those. The calculator converts the fuel you already burned into delivered heat using the fuel's heat content and your current system's efficiency, then prices each replacement on that load. If you already know the delivered heat, choose MMBtu and enter it directly.

Do heat pumps work in cold climates?

Yes, with the right unit and installation. ENERGY STAR's cold-climate designation requires third-party testing at 5°F, a COP of at least 1.75 at 5°F, and at least 70% of rated capacity at 5°F; ducted split systems must also reach HSPF2 8.1. Below the balance point, a heat pump uses resistance backup or a dual-fuel furnace, so the effective efficiency falls. Ask your installer for a Manual J load calculation and the balance-point temperature, not just the headline rating.

Sources & notes

Primary data and reference material used on this page.

  1. ENERGY STAR — Air-Source Heat Pumps — cold-climate performance testing at 5°F; dual-fuel systems; a federal tax credit of up to $2,000 for qualifying units installed through 2032
  2. ENERGY STAR — Heat Pump Equipment Key Product Criteria — HSPF2 ≥ 7.8 for standard split systems; cold-climate ≥ 8.1 ducted and ≥ 8.5 non-ducted; COP at 5°F ≥ 1.75 and capacity at 5°F ≥ 70% of the 47°F rating
  3. EIA — Electric Power Monthly, Table 5.6.A — U.S. residential average price of 18.17¢/kWh, September 2026
  4. EIA — U.S. Price of Natural Gas Delivered to Residential Consumers — 12 months through August 2026 averaged $19.47/Mcf; the latest month, August 2026, was $27.05/Mcf, or about $2.61/therm at 10.37 therms per Mcf
  5. EIA — Weekly Heating Oil and Propane Prices, residential propane — U.S. residential propane averaged $2.813/gal in the week of Nov. 23, 2026, excluding taxes
  6. EIA — Weekly Heating Oil and Propane Prices, residential heating oil — U.S. residential heating oil averaged $5.468/gal in the week of Nov. 23, 2026, excluding taxes
  7. EIA — Units and calculators explained: British thermal units (Btu) — 1 therm = 100,000 Btu; propane = 91,452 Btu/gal; heating oil = 138,500 Btu/gal; worked example of comparing fuels in dollars per million Btu
  8. EIA — How do I convert natural gas prices in dollars per cubic feet to dollars per therm? — 2025 average heat content of about 1,037 Btu per cubic foot; 1 Mcf = 10.37 therms
  9. EPA eGRID 2023 Summary Tables — U.S. total output emission rate of 770.9 lb CO₂e per MWh, used here as 0.771 lb/kWh
  10. EPA — Greenhouse Gas Emission Factors Hub — stationary combustion factor of 53.06 kg CO₂ per million Btu for natural gas, used here as 11.7 lb/therm
Editorial noteFigures are rounded for readability; calculations use the unrounded inputs shown in the methodology. Prices and grid factors change — treat every result as an estimate, not a bill.